What is ASHRAE 55?

Definition

ASHRAE 55 is the ASHRAE standard Thermal Environmental Conditions for Human Occupancy. It defines the combinations of temperature, humidity, air speed and radiant conditions, together with occupant activity and clothing, that a substantial majority of occupants will find thermally acceptable.

What it is

ASHRAE 55 uses six factors to describe thermal comfort: metabolic rate, clothing insulation, air temperature, mean radiant temperature, air speed and humidity. Comfort depends on all of them together, not on air temperature alone.

The standard offers methods for determining acceptable conditions, including the predicted mean vote model for mechanically conditioned spaces and an adaptive model for occupant-controlled naturally conditioned spaces. It also addresses local discomfort such as drafts, radiant asymmetry and vertical temperature differences.

Who it applies to / where it is used

ASHRAE 55 is used by HVAC designers, commissioning agents and owners of offices, schools, healthcare outpatient areas, laboratories and public buildings. Green building and wellness rating systems reference it for thermal comfort credits.

How it is measured / what evidence it needs

Design compliance is shown with calculations. In operation, comfort is checked through measurement and occupant feedback.

  • Zone air temperature and humidity trends
  • Air speed and radiant conditions where relevant
  • Occupant surveys on thermal satisfaction
  • Setpoint and schedule records by zone

How Aqueduct helps

Aqueduct maps each zone against ASHRAE 55 comfort bands and shows where comfort and energy pull against each other.

  • Zone temperature and humidity at 60-second refresh through aQ AirSafe
  • Comfort band views that flag zones too warm, too cool or too humid
  • Setpoint adjustment where control is enabled, with owner approval
  • Energy effect of comfort changes tracked through aQ EnergySmart
Questions

ASHRAE 55: common questions

ASHRAE 55 defines acceptable thermal conditions using six factors: metabolic rate, clothing, air temperature, radiant temperature, air speed and humidity.

It is a method for naturally conditioned spaces where occupants control windows. Acceptable indoor temperatures shift with recent outdoor temperatures.

ASHRAE 55 is a voluntary standard unless a code, contract or rating system requires it. Many green building and wellness programs reference it.

Aqueduct tracks zone conditions against comfort bands and flags problem zones. Where control is enabled, with owner approval, it adjusts setpoints and tracks the energy effect.